Marine generator sets | Authorized distributor in Taiwan
Baudouin 6W105ES
6.7 L in-line 6-cylinder emergency marine genset, ESP 132/136 kWe
120/136 kWePRP output (50/60 Hz)
1500/1800 rpmSpeed (50/60 Hz)
6.7 LDisplacement
1390 kgDry weight
Features
Features
Individual cylinder heads
According to the manufacturer, individual cylinder heads allow quick servicing and minimal downtime.
Fuel system safety
Double-wall fuel injection pipes with leak detection; duplex fuel filters can be changed while the engine is running.
No derating at class temperatures
According to the manufacturer, ratings comply with the classification societies' maximum temperature definition (45°C ambient, 32°C raw water) without power derating.
Specifications
Full specifications
| Type | Emergency marine generator set |
|---|---|
| Engine cylinders | In-line 6-cylinder (L6) |
| Bore × stroke | 105 × 130 mm |
| Displacement | 6.7 L |
| Output (50/60 Hz) | ESP 132/136 kWe; PRP 120/136 kWe |
| Frequency / speed | 50 Hz / 1500 rpm; 60 Hz / 1800 rpm |
| Voltage | 380–415 V (50 Hz); 440–480 V (60 Hz) |
| Emissions (as stated by the manufacturer) | Varies by rating; see ratings table |
| Fuel injection | Mechanical fuel injection |
| Cooling system | Two-stage cooling circuit with integrated HT thermostatic valve, tube-type heat exchanger |
| Idle speed | 650 rpm |
| Electrical system | 24 V DC insulated system, electric starter, 55 A battery charger |
| Alternator | 50/60 Hz, 4 poles, brushless excitation, electronic voltage regulation |
| Protection / insulation class | IP23, marine impregnation; insulation / heating class H/H |
| Alternator bearing | Single bearing |
| Dimensions | L 2450 × W 1059 × H 1313 mm |
| Dry weight | 1390 kg |
| Power standard | ISO 3046-1:2002 |
Output by duty rating About duty ratings →
| Rating | Frequency Hz | kVA | kWe | Speed rpm | IMO |
|---|---|---|---|---|---|
| ESP | 50 | 165 | 132 | 1500 | — |
| PRP | 50 | 150 | 120 | 1500 | II |
| ESP | 60 | 170 | 136 | 1800 | — |
| PRP | 60 | 170 | 136 | 1800 | II |
Notes
- PRP (prime power) as defined by the manufacturer: unlimited running hours, no more than 500 hours per year at full load, load variation up to 75% of rated power, and 10% overload available for 1 hour in every 12 hours.
- ESP (emergency standby power) as defined by the manufacturer: up to 200 running hours per year, load variation up to 110% of prime power, and an average load factor not exceeding 70% of the ESP rating.
- Emissions are as stated by the manufacturer; applicable certification depends on the delivered version and its certificates.
- Specifications as published by the manufacturer; the delivered configuration and the manufacturer's latest spec sheet govern.
- Where the emissions column shows "—", please contact Hallmark Marine to confirm the applicable emission regulations and certificates.