Products and specifications | Authorized distributor in Taiwan
Sonihull Sonihull Duo
A compact control unit supplied with 2 ultrasonic transducers, for AC or DC power
Features
Features
Dry-side installation
Transducers are bonded with epoxy to the dry side of the hull, sea chests, coolers or pipework, with no through-hull penetrations.
Suitable materials
Suitable for materials that transmit ultrasound well, including FRP, GRP, aluminium, steel, stainless steel, titanium and rigid plastics; professional installation is recommended for FRP/GRP sandwich construction; not suitable for wooden hulls.
Status indication
A green "System OK" LED shows that the system is running normally.
Low DC voltage warning
The power LED flickers when the DC supply is between 11.9 and 12.4 V; on battery-powered installations this indicates poor battery condition.
Maintenance
Under the manufacturer's maintenance schedule, the crew carries out weekly and monthly checks and renews the transducer gel every 6 months; a manufacturer service engineer services the system every 5 years or at dry-docking.
Specifications
Full specifications
| Model code | SH02 |
|---|---|
| Supply voltage | 110/230 V AC 50/60 Hz or 12–24 V DC (1.2 A) |
| AC voltage selection | Automatic |
| Average power consumption | 11 W (AC) / 10 W (DC) |
| DC fuse | 5 A |
| Ultrasonic frequency | 19.5–55 kHz |
| Ultrasonic transducers | 2 supplied |
| Transducer cable length | 7.5 m (extendable to 20 m) |
| Transducer protection | IP68 |
| Transducer dimensions | Ø76×75 mm |
| Mounting ring dimensions | Ø95×24 mm |
| Control unit protection | IP65 |
| Control unit dimensions (W×H×D) | 175×130×75 mm |
| Weight | Control unit 2 kg; transducers 3.5 kg; total boxed 5.4 kg |
| Maximum operating temperature | 40°C |
| Power supply approvals | UL, CE (power-supply approvals, not system or performance certifications) |
| ATEX (94/9/EC) | Zone 0 transducers available as an option; the control unit is suitable for Zones 1 and 2 when fitted in a separate cabinet |
Notes
- The Duo is also known as the 02.
- The number of transducers is configured after assessing vessel type, structure and areas to be protected.
- Power consumption is measured during operation at 230 V AC.
- The system prevents biofouling; it cannot remove established hard fouling, so surfaces must be cleaned before installation.
Equipment selection, installation guidance and sea trials, scheduled maintenance and repair, and genuine parts. For parts enquiries, please provide the brand, model, serial number and vessel name. Warranty follows the manufacturer's terms and is decided case by case.